MODEL: QCC-ST-019 ASTM D 1558 The instrument consists of a needle attached to a spring loaded plunger, the stem of which is calibrated to read 0 to 40 kg division. Long stem is graduated at every 12.5mm to read depth of penetration and for use with needles of larger areas. The small penetration stem is also graduation in 12.5mm division…
MODEL: QCC-ST-032 As Per IS 2386 (P-III) Specification : Specific Gravity is the ratio of the weight in air of a given volume of a material at a standard temperature to the weight in air of an equal volume of distilled water at the same stated temperature. The Pycnometer Bottle can be used to test a wide range of materials…
MODEL: QCC-ST-038 IS 2720 (PART XIV), ASTM D 4253 & ASTM D 4254 The equipment is used for the determination of the relative density of cohesion less free draining soils and meets the essential requirements. Specification : The equipment consists one each of: Vibratory table, with a cushioned steel vibrating decks about 75cm x 75cm. It has a frequency of…
MODEL: QCC-ST-088, 089 'ROTAP' Sieve Shaker (QCC-ST-088) To make process of sieving simpler and quicker, Rotap sieve shaker is useful , this produces circular shaking of the sieves. At the same time the sieves are tapped. The mechanism for imparting circular action and topping is oil immersed in a tank and in motorized. The shaker can accommodate upto 7 nos.…
MODEL: QCC-ST-027 ASTM D1556, AASHTO T191 The Sand Density Cone and accessories are used for determination of the insitu (in-place) density of soils. The apparatus is restricted to tests in soils containing particles not larger than 2" (50.8 mm) in diameter. The Sand Density Cone consists of a double cone assembly with a brass valve and comes supplied with a…
MODEL: QCC-ST-013 ASTM D 2419, AASHTO T 176 Used to determine the relevant proportions of clay-like or Plastic fines and dust in granular soils & fine aggregate Consists of: 1. Acrylic graduated cylinder (4 nos.) 2. Rubber stopper for cylinder (4 nos.) 3. Graduated Steel rule 450 mm 4. Funnel 100 mm plastic 5. Aspirator bottle 5 lts plastic with rubber cock 6. Stand for the…
MODEL: QCC-ST-026 As Per IS 2720 (P-XXVIII) BS 1377-9 Specification : The soil testing equipment is used for determination of the dry density of compact, fine, medium grained soils and for layers not exceeding 50cm thickness. A circular hole is dug into the ground, all the soil from within it collected, weighed and dried, and the hole back filled with…
MODEL: QCC-ST-002 IS 2720 (PART-VII) ASTM D 427, BS 1377, AASHTO T 92. Shrinkage limit is the maximum water content at which a reduction in water content does not cause an appreciable reduction in volume of the Soil Mass. At shrinkage limit, on further reduction in water, air enters in to the voids of soils and thus keeps the volume…
MODEL: QCC-ST-004 IS 2720 (PART IV) For determining the liquid limit of soils. This is specially useful to obtain reliable and accurate results of those soil which have low plasticity index. The percentage moisture contents determined when cone with half angle for 15-30 minutes under a total sliding weight of 148 gm penetrates 25mm gives the liquid limit. Contact…
MODEL: QCC-ST-005 ASTM D 422 AASHTO T 88, BS 1377-2. Used for grain size analysis of soils where more than 10% of the material will pass through 75 microns B.S. sieve. Manufactured from clear transparent glass having uniform clarity throughout the upper end on which density scale is engraved. The scale range is 0.995 to 1.030 0 density (gms./cc) at…
MODEL: QCC-ST-023 As Per IS 2720 (P-II), ASTM D 4944 AASHTO T 217 Specification : Moisture content of soil is generally measured as a ratio of the weight of water to the weight of solids, expressed in percentage. As soil behavior depends on its moisture content, it is one of the basic parameters defining the soil condition. The 'Moisture' content…
MODEL: QCC-ST-093 IS :460 (Par t-I, II) 1978 Test Sieves is a common laboratory requirement. Sieves are used for sieving of chemical powders, medical powders, aggregate, sand soil and cement etc. These sieves are manufactured as per various standards like IS, BS, ASTM, DIN etc. In Civil Engineering it is a common practice to use sieves for gradation and particle…
MODEL: QCC-ST-095 IS :460 (Par t-I, II) 1978 Test Sieves is a common laboratory requirement. Sieves are used for sieving of chemical powders, medical powders, aggregate, sand soil and cement etc. These sieves are manufactured as per various standards like IS, BS, ASTM, DIN etc. In Civil Engineering it is a common practice to use sieves for gradation and particle…
MODEL: QCC-ST-059 It is designed to determine the swelling pressure developed by soil specimens moulded to desired densities at known moisture contents, when soaked in water. The load applied to restrain the swelling is transferred on to a load measuring proving ring through a perforated swell plate and a load transfer bar. The proving ring is attached to the lead…
MODEL: QCC-ST-061 IS 2720 (PART X) ASTM T 208 This is similar to above with the added advantage of a motorized drive permitting constant rates of stain. Specification : Comprises a screw operated load frame, cap.5000kg with a gear box and motor drive giving 1.25 mm/min. Rates of strain, a pair of cone seating, adaptor for proving ring, and stain…
MODEL: QCC-ST-039 The extractor frame is used for taking out soil samples compacted or undisturbed, from 100mm dia and 150mm dia cylinders such as Core Cutters, Proctor moulds, C.B.R. moulds etc. Specification: It consists of a 50Kn capacity hand operated, hydraulic jack mounted on a suitable frame. Two plungers, one for 4"/100mm dia and the other of 6"/150mm dia moulds…
MODEL: QCC-ST-031 As Per IS 2720 (Part XBII)- 1966 BS 1377; EN DD ENV 1997-2; ASTM D2434; AASHTO T215 Clays and silts are tested using the technique. Flow of water through the specimen is observed by monitoring the rate of fall of water in the tube. It is essential that soils of very low permeability are sealed inside the cylinder…
MODEL: QCC-ST-088, 089 Vibratory Sieve Shaker accommodates 8in and 200mm test sieves. It combines the latest in electronic control with proven separation technology for fast, accurate separations of materials. The quiet, compact benchtop unit offers complete control of multi-directional agitation for optimum performance based on material type. The optimal size range is dependant on material type but typically, particles between from No.…