MODEL: QCC-AG-007 As Per IS 2386 (P-IV) Specification : The selection of proper aggregate for a given application is essential to attain the desired quality. Various characteristics are required to be determined for the selection of appropriate aggregate from the wide range available. Aggregate crushing value test apparatus is used for measuring resistance of an aggregate to crushing. Made of…
MODEL: QCC-AG-008 As Per IS 2386 (P-IV) Specification : Aggregate Impact Value Test Apparatus is used for determining the aggregate impact value. The Sturdy Construction consists of a base and support columns to form a rigid framework around the quick release trigger mechanism to ensure an effective free fall of the hammer during test. The free fall can be adjusted…
MODEL: QCC-AG-003 AS PER IS: 2386 (Part- III) Determines bulk density or unit weight of aggregates. Specifications: Calibrated cylindrical measures of sheet iron with handles. Consists of 3 measures one each 3 liters capacity, 15 liters capacity and 30 liters capacity. Complete with one tamping rod, round, 16mm dia. and 600mm long, one end rounded. Contact Now Enquiry Now
MODEL: QCC-AG-005 IS 2386 (PART-III) & BS 812 For Density Tests on Aggregates as per Procedure Laid Down. Specification : Made of Brass/GI with Stainless steel Wire Mesh 6.3mm/4.75mm size Ruggedly Constructed, Approximately 20cm dia x 20cm high. Complete with Handle. Contact Now Enquiry Now
MODEL: QCC-AG-012 BS 812 For Testing Aggregates for Resistance to Abrasion. Specification : It consists of a disc rotating about a shaft connected to a reduction gear box coupled to a motor. The disc rotates at 28-30 RPM. Under the rotating disc is a tray with an outlet to facilitate the removal of sand. Two Conical Hoppers are mounted on…
MODEL: QCC-AG-002 As Per IS 2386 (P-I) Specification : Aggregates which are flaky and/or elongated will often lower the work ability of a concrete mix and may also affect long term durability. In bituminous mixtures, flaky aggregates make for a harsh mix and may also crack and break up during compacting by rolling. The flakiness of aggregate is determined by…
MODEL: QCC-AG-001 As Per IS 2386 (P-I) Specification : Aggregates which are flaky and/or elongated will often lower the work ability of a concrete mix and may also affect long term durability. In bituminous mixtures, flaky aggregates make for a harsh mix and may also crack and break up during compacting by rolling. The flakiness of aggregate is determined by…
MODEL: QCC-ST-087 Carries upto 7 sieves of 200mm or 300m, 450mm diameter. The shaker is driven by a ¼ H.P. Motor through a reduction gear immersed in oil. The sieve table does not rotate but is inclined from the vertical axis and the direction on inclination charges progressively in clockwise direction. If the stop pin below the table is removed,…
MODEL: QCC-AG-014 The laboratory jaw Crusher is designed for fast crushing of Aggregates, Ores, Minerals, Coal, Coke, Chemicals and other similar materials. It is compact and of rugged construction for general laboratory of small pilot plant operations. Two jaws of manganese steel are provided in this laboratory jaw Crusher. The moveable jaw produces tow blows for every revolution, thus reducing…
MODEL: QCC-AG-015 The Laboratory Pulverize is a disc type grinder, designed to grind virtually any material to produce a fine mesh sample in one operation. The instrument is useful for assaying , mining and for metallurgical, quarrying, aggregate processing, chemical, geological and industrial laboratories. It is a self contained grinder, with a rotary disc, having a planetary movement in a…
MODEL: QCC-AG-010 As Per IS 2386 (P-IV) ASTM: C131, AASHTO T-96 Specification : Los Angeles Abrasion Testing Machine is used for determining the resistance to wear of small size coarse aggregates and crushed rock. The abrasion testing machine consists of a Closed hollow cylindrical steel drum rotating around its horizontal axis on ball bearing units mounted on a sturdy base…
MODEL: QCC-AG-006 As Per IS: 1607-1960 Specification : Riffle sample divider is required for the rapid collection of true representative samples from aggregates, sand and fillers. Riffle Sample Divider consists of a metal box fitted with a series of chutes of equal width which discharge the material alternatively in opposite directions into separate pans. The chutes of the riffle are…
MODEL: QCC-ST-088, 089 'ROTAP' Sieve Shaker (QCC-ST-088) To make process of sieving simpler and quicker, Rotap sieve shaker is useful , this produces circular shaking of the sieves. At the same time the sieves are tapped. The mechanism for imparting circular action and topping is oil immersed in a tank and in motorized. The shaker can accommodate upto 7 nos.…
MODEL: QCC-AG-009 As Per IS: 2386 (Part III) Specification : The density of hardened concrete specimens such as cubes and cylinders can be quickly and accurately determined using a Specific Gravity / Buoyancy Balance. The apparatus consists of a rigid support frame, incorporating a water tank mounted on a platform. A mechanical lifting device is used to raise the water…
MODEL: QCC-ST-093 IS :460 (Par t-I, II) 1978 Test Sieves is a common laboratory requirement. Sieves are used for sieving of chemical powders, medical powders, aggregate, sand soil and cement etc. These sieves are manufactured as per various standards like IS, BS, ASTM, DIN etc. In Civil Engineering it is a common practice to use sieves for gradation and particle…
MODEL: QCC-ST-095 IS :460 (Par t-I, II) 1978 Test Sieves is a common laboratory requirement. Sieves are used for sieving of chemical powders, medical powders, aggregate, sand soil and cement etc. These sieves are manufactured as per various standards like IS, BS, ASTM, DIN etc. In Civil Engineering it is a common practice to use sieves for gradation and particle…
MODEL: QCC-ST-088, 089 Vibratory Sieve Shaker accommodates 8in and 200mm test sieves. It combines the latest in electronic control with proven separation technology for fast, accurate separations of materials. The quiet, compact benchtop unit offers complete control of multi-directional agitation for optimum performance based on material type. The optimal size range is dependant on material type but typically, particles between from No.…